itenzh-hans
Gavorrano
Gavorrano
Firenze
Napoli
+39 0566 58619 info@opus-automazione.it Operational Office: Via Dell' Argento, 12, Gavorrano, 58023 GR, Italia
+39 055 433044 info@opus-automazione.it Via Pietro Fanfani, 19 b, Firenze, 50127 FI, Italia
+39 345 6317087 info@opus-automazione.it Via Lucullo, 71, Bacoli (NA), 80070, NA, Italia

Immissions analysis cabin

Product Description

Analyzed parameters: O3, CO, SO2, NOx, PM1, PM2.5, PM10; weather parameters

Product description

The continuous immissions analysis system of the gas inlets is made up of a prefabricated and conditioned box complete with eye bolts for handling the continuous and intermittent analysis of:

  • Ozone (O3)
  • Carbon monoxide (CO)
  • Sulfur dioxide (SO2)
  • PM 1
  • PM 2.5
  • PM 10
  • Weather

The system includes electrical control and pneumatic distribution to interface with the analysis modules and the sampling system. The rack created forms a complete analytical system integrated with a data acquisition system consisting of:

  • Desktop PC for data acquisition and processing
  • DatiMQA software for the acquisition, engineering, normalization, archiving and comparison of data within the limits of the law, in compliance with Legislative Decree 155/2010 and the Arpa / Ispra guidelines.

Main features

  • Dimensions 4 × 2.2 × 2.2m
  • Eye bolts for lifting
  • Air conditioning system
  • 220 Vac power supply
  • Power 3,5 Kw
  • ETH network connections, bus mod RS485
  • Integrated weather station